Skid Mounted Refueling Station
video
Skid Mounted Refueling Station

Skid Mounted Refueling Station

The Skid Mounted Refueling Station integrates a double-wall explosion-proof storage tank, explosion-proof transfer pump, dispenser, flow meter, and control system on one skid. The unit is assembled and connected at the factory before shipment. Tank capacity ranges from 30,000 L to 55,000 L and can be customized.
Send Inquiry
Product Details ofSkid Mounted Refueling Station

Product Overview

 

The Skid Mounted Refueling Station integrates a double-wall explosion-proof storage tank, explosion-proof transfer pump, dispenser, flow meter, and control system on one skid. The unit is assembled and connected at the factory before shipment. Tank capacity ranges from 30,000 L to 55,000 L and can be customized.

 

Technical Specifications

 

Parameter

Specification

Storage Tank Capacity

30,000–55,000 L

Overall Dimensions

12,191 × 2,438 × 2,591 mm

Tank Material

Q235B carbon steel; Q355B optional

Tank Wall Structure

Double-wall

Tank Thickness

5, 6, or 8 mm

Tank Configuration

Single or dual compartment

Compatible Fuels

Diesel, gasoline, biodiesel (B5–B20)

Refueling Flow Rate

5–75 L/min

Flow Meter

Piston flow meter

Metering Error

≤ ±0.30%

Minimum Measurement Value

5 L

Power Supply

110 V / 220 V / 380 V

Power Rating

5.5 kW / 6.7 kW, depending on configuration

Ambient Temperature

-40°C to +60°C

Relative Humidity

≤ 86% RH

Pump Inlet Vacuum Level

≥ 54 kPa

Explosion-Proof Rating

Ex db eb ib mb IIA T3 Gb

 

Refueling System Configuration

 

Integrated Pumping and Dispensing System

The explosion-proof transfer pump, dispenser, piping, and control system are assembled and connected at the factory. The refueling hose is made of oil-resistant, weather-resistant, anti-static nitrile rubber.

Fuel Metering and Dispensing

A digital flow meter is fitted as standard for refueling measurement.

Single- or Dual-Compartment Tank

The tank is available with one or two compartments. The dual-compartment model stores two fuel types at the same time, with separate dispensers to avoid cross-contamination.

Fuel-Level Monitoring

An optional remote liquid-level monitoring system connects to a mobile app or backend platform. It tracks tank inventory and fuel consumption, including when the site is unmanned.

 

Customization Options

 

Tank Capacity and Construction
Capacity, steel grade, wall thickness, and compartment configuration can be specified according to project requirements.

Fuel Type and Dispensing Requirements
The station can be configured for diesel or gasoline, with the dispensing arrangement matched to the site.

Metering and Monitoring
Metering precision can be specified to suit the operating conditions.

Electrical and Site Requirements
Available power supply options include 110 V, 220 V, and 380 V. The final electrical and explosion-proof configuration should match the installation environment and destination-market requirements.

 

71

 

Refueling Applications

 

Fleet Refueling
Centralized fuel storage and dispensing for commercial vehicle fleets.

Construction and Mining Operations
Diesel and other compatible fuels for construction machinery and mining equipment. The unit can be relocated as work sites change.

Industrial and Logistics Sites
A dedicated on-site refueling point for industrial equipment and logistics operations. It requires less space than a conventional fuel station.

Remote Operating Locations
Refueling at sites with limited grid power or on-site supervision.

 

Product Case

 

Safety & Quality Verification

 

Tank Pressure and Leak Testing
Pressure testing is carried out on the tank. The tank complies with ASME, PED, CE, and other standards.

Explosion-Proof Equipment
Explosion-proof pump and electrical components are fitted for use in hazardous areas.

Fuel Containment and Overfill Protection
Leak detection and overfill protection are included.

Materials and Corrosion Protection
The tank is made of Q235B carbon steel, with Q355B available as an upgrade. The coating system is a zinc-rich epoxy primer with a polyurethane or fluorocarbon topcoat, for resistance to salt spray and UV radiation outdoors.

 

Product shipment

 

FAQ

 

Q: Can the station dispense more than one type of fuel?

A: Yes. The dual-compartment model stores two fuel types, with separate dispensers to avoid cross-contamination.

Q: Can the station operate at a site without grid electricity?

A: Yes. Optional solar panels or a backup generator can power the dispenser for off-grid operation.

Q: What information is needed for a quotation?

A: Please provide the fuel type, required tank capacity, target flow rate, number of dispensing points, power supply, destination country, and any project-specific requirements.

Q: Can the station meet the certification requirements of different markets?

A: Region-specific certification (CE, UL, ATEX) can be arranged according to the destination market. Please state the destination country when inquiring.

Q: What maintenance and support are available?

A: Check hoses and valves monthly, and inspect the tank and replace the filter annually. We provide on-site setup guidance, operator training, a 12-month warranty on core components, and 24/7 technical assistance.

Q: What is the lead time?

A: Lead time is typically 30–45 days after order confirmation and receipt of the deposit. The exact time depends on tank capacity, configuration, and certification requirements, and is confirmed in the quotation.

Q: What is the minimum order quantity?

A: Each unit is built to the customer's specification, and quantity is discussed per project. Please send your requirements to receive a quotation.

Hot Tags: skid mounted refueling station, China skid mounted refueling station manufacturers, suppliers, factory, Containerized Refueling Station, Emergency Fuel Station, Skid Mounted Diesel Station, skid mounted fuel station, Skid Mounted Fuel System, Skid Mounted Fuel Tank

Send Inquiry

(0/10)

clearall