Skid-mounted Refueling Unit Manufacturer for Industrial Fuel Supply

 

Our skid-mounted refueling units combine fuel storage, transfer, metering and dispensing in one factory-assembled skid. Units are built for diesel, gasoline and other approved liquid fuels, with capacity, dispensing and safety configuration set to the project requirements.

Shandong Jingcai Industry and Trade Co., Ltd. is based in Qufu, Jining, Shandong. We serve the petrochemical, energy storage and industrial safety sectors, with a team of 30 working in materials R&D, engineering applications and technical services.

 
 
Product Range & Applications

 

Product Type

Key Features

Typical Applications

Construction Site Machinery Fueling Device

Integrated fuel storage and on-site dispensing

Construction sites and remote equipment areas

Mobile Refueling Skid

Skid-mounted fuel storage and dispensing system

Mining, industrial facilities, and relocatable fueling points

Bulk Fuel Dispensing System

Integrated fuel transfer, metering, and dispensing

Commercial facilities, industrial yards, and fleet depots

Explosion-proof Refueling Skid

Fuel dispensing system with specified explosion-protection components

Hazardous areas requiring appropriate electrical protection

Double Wall Tank Skid Station

Inner tank with secondary containment

Sites requiring additional fuel containment

 

Capacity Series & Selection

 

Series

Capacity

Typical Configuration

Typical Applications

Standard

5,000–50,000 L

Tank, pump, flow meter, hose reel, and nozzle

Industrial yards, logistics depots, and bus stations

Containerized

10,000–30,000 L

Containerized housing for enclosed equipment installation

Ports, remote hubs, and exposed operating environments

Smart Automated

10,000–40,000 L

Optional IC/ID card readers, fuel tracking, and tank monitoring

Mining and multi-vehicle fleets

Portable Mini

1,000–3,000 L

Compact frame for transport by light truck, subject to vehicle capacity

Farms, forestry sites, and emergency generators

 

Technical Specifications

 

Parameter

Specification

Tank Capacity

1,000–50,000 L, depending on model

Tank Material

Carbon steel

Fuel Type

Diesel, biodiesel, gasoline, kerosene, or other specified fuels, subject to component compatibility

Pump Type

12 V / 24 V DC or AC electric

Flow Rate

50–500 L/min, depending on pump configuration

Dispensing Points

Single or dual

Standard Hose Length

15 m

Dispensing Accessories

Nozzle; automatic shut-off optional

Overfill Prevention

Optional, depending on configuration

 

Safety Configuration

Secondary Containment

Double-wall tank designs provide secondary containment around the inner tank. Containment capacity and leak detection requirements depend on the tank design and applicable project regulations.

Fire and Overfill Protection

Overfill prevention, pressure-vacuum vents, and other safety devices can be specified according to the tank design and applicable requirements. Automatic fire suppression is an optional configuration where available.

Explosion-proof electrical system

Motors, control panels, junction boxes and wiring are available with Ex-proof, ATEX or IECEx ratings for hazardous zones.

Interstitial Leak Detection

Electronic or optical monitoring can be specified to detect liquid or abnormal conditions in the space between the tank walls.

 

Dispensing, Metering & Control

 

 

Pump Selection

Select the pump according to the specified fuel, required dispensing flow, available power supply, and transfer conditions.

 

Fuel Metering

Positive displacement meters and pulse-output meters can be specified according to measurement and fuel-accounting requirements. Ticket printing is optional where supported by the selected system.

 

Fleet Fuel Management

IC/ID card readers, RFID vehicle identification, and fuel-management software can support user access control and fuel consumption records. Specify the required reporting and remote monitoring functions when requesting a quotation.

 

 

 

Installation & Operating Conditions

Foundation and Utilities
Prepare a stable, level foundation according to the loaded tank weight, skid dimensions, and installation design. Confirm the required power supply, grounding, and lightning protection arrangements against the equipment specifications and local regulations.

 

Relocation and Transport
Confirm skid dimensions, gross weight, lifting points, and transport access before relocating the unit between sites.

 

Off-grid Power
Solar power with battery storage or generator integration can be considered for sites without a suitable grid supply, subject to the selected pump and control-system requirements.

 

Extreme Climates
Canopies, thermal insulation, and fuel heating or cooling options can be evaluated according to the expected ambient temperature and fuel properties.

Bulk Fuel Dispensing System manufacturers

 

Customization Process

 

 

1.Submit the fuel type, required capacity, daily consumption and operating conditions.
2.Provide site dimensions, power supply details, applicable standards and drawings.
3.Review the tank and dispensing configuration with our engineering team.
4.Confirm the technical specification, quotation, delivery terms and inspection requirements before production.

We customize tank compartments, pump brands, explosion-proof ratings (ATEX, UL or IECEx) and safety features to match the destination country’s codes.

 

Bulk Fuel Dispensing System suppliers

 

Quality Control & Compliance

Material verification: Certified carbon steel with mill test certificates.

 

Welding and NDT: Critical tank welds are inspected by radiographic and ultrasonic testing, performed by certified welding personnel.

 

Pressure and leak testing: Each storage compartment undergoes hydrostatic and pneumatic leak tests, followed by sandblasting and anti-corrosion coating.

 

Factory acceptance test (FAT): Pumps, meters and safety interlocks are function-tested before dispatch. A FAT report and quality documents are supplied with each order.

 

Certifications & Standards
ISO 9001 quality management system
CE and Ex-proof certification for electrical components
Design and safety references: API 650, NFPA 30 / 30A

 

Delivery, Documentation & After-sales

 

Shipping

Units are blocked and secured inside shipping containers or on flat-rack vessels. Sensitive components are wrapped in weatherproof protection.

01

Documents

Operating and maintenance manuals are supplied with the FAT report and quality documents. The full document list is confirmed in the purchase order.

02

Installation support

Units arrive pre-assembled. We provide remote video guidance and, on request, dispatch engineers for installation supervision, commissioning and operator training.

03

Maintenance and spares

Access hatches, removable filter elements and self-diagnostic control panels simplify routine service. We provide maintenance schedules for filter cleaning, pump lubrication checks and annual P-V valve testing. Wear parts including seals, nozzles, meters and filters are available.

04

Warranty

12 months on main components (pumps, meters and structure), with technical support and spare parts supply.

05

 

 

FAQ

 

 

Q: What is the typical lead time?

A: Skid-mounted refueling units are typically delivered within 30–60 days after the specification and drawings are confirmed. Larger capacity, double-wall construction, explosion-proof certification and automation extend the schedule. The exact lead time is stated in the quotation.

Q: What affects the price of a unit?

A: Tank capacity, single or double-wall construction, pump type and flow rate, meter type, explosion-proof rating, automation functions, container housing, and the documents or inspections required for the destination.

Q: How do I determine the tank capacity?

A: Base it on daily fuel consumption and the interval between fuel deliveries, then add a reserve. Tank size should also fit the available site area and transport route.

Q: When should I choose a skid-mounted unit over a fixed station?

A: A skid-mounted unit suits temporary, relocatable or remote fueling points that need fast setup. A fixed station is better suited to permanent, high-volume operation with public access.

Q: Do I need a permit to install and operate the unit?

A: Fuel storage is regulated in most countries, and requirements vary by location and tank capacity. Check with the local authority before ordering. We provide drawings and certificates to support the application.

Q: Can the fuel type be changed after delivery?

A: Pump, seals and meter are matched to the specified fuel. Contact us before switching fuels, especially from diesel to gasoline, because compatibility and explosion-proof requirements need to be reviewed.

Q: Can the unit be used to sell fuel to third parties?

A: Units are designed for internal fueling. Fuel sales to third parties are subject to local metrology and licensing rules, and may require approved meters. State this requirement when requesting a quotation.

Q: Can the buyer arrange inspection before shipment?

A: Yes. Buyer-appointed inspection or a third-party agency such as SGS or BV can be arranged. State the inspection scope and standards in the purchase order, and we coordinate the schedule at our factory.

As one of the most professional skid-mounted refueling unit manufacturers and suppliers in China, we also support customized service. With abundant experience, we warmly welcome you to wholesale high quality skid-mounted refueling unit in stock here from our factory. Contact us for free sample.

Bulk Fuel Dispensing System, Construction Site Machinery Fueling Device, skid mounted refueling unit

(0/10)

clearall