Self Contained Fuel Station for Ports
video
Self Contained Fuel Station for Ports

Self Contained Fuel Station for Ports

The Self Contained Fuel Station for Ports provides a compact, integrated fuel storage and dispensing solution for port operators, fleet service providers, and equipment distributors. Its 500–7,000 L capacity range supports different on-site fuel supply requirements.
Send Inquiry
Product Details ofSelf Contained Fuel Station for Ports

Product Overview

 

The Self Contained Fuel Station for Ports provides a compact, integrated fuel storage and dispensing solution for port operators, fleet service providers, and equipment distributors. Its 500–7,000 L capacity range supports different on-site fuel supply requirements.

 

Technical Specifications

 

Model

Tank Capacity

Dimensions (L × W × H)

Flow Rate

Reference Weight (Diesel/Gasoline)

JC-M500

500 L

0.8 × 1.2 × 1.2 m

0–40 L/min

Not specified

JC-M1000

1,000 L

1.05 × 1.375 × 1.03 m

0–40 L/min

Not specified

JC-M2000

2,000 L

2.6 × 1.1 × 1.0 m

0–70 L/min

1.65 / 1.45 t

JC-M3000

3,000 L

2.7 × 1.1 × 1.1 m

0–70 L/min

2.22 / 2.55 t

JC-M5000

5,000 L

3.1 × 1.5 × 1.45 m

0–70 L/min

4.0 / 3.5 t

JC-M7000

7,000 L

3.99 × 1.5 × 1.45 m

0–70 L/min

8.5 / 7.4 t

 

Structure and Key Components

 

Separate Control and Dispensing Compartments
The unit has a two-compartment door arrangement. The electrical control compartment houses the control panel and display, while the dispensing compartment accommodates the fuel nozzle and hose, separating the operating areas for easier access.

Integrated Pump and Piping System
The internal assembly includes the pump, filter, solenoid valve, piping, and associated wiring. Fixed component positions and organized routing facilitate inspection, filter replacement, and pump maintenance.

Top-Mounted Fuel Connections
The upper section provides connections for fuel intake, a breather valve, and an overfill-prevention connection. These interfaces support fuel delivery from a tanker truck when the unloading arrangement and site procedures are compatible with the selected configuration.

Forklift-Handling Base
A channel-steel base incorporates forklift pockets for handling and repositioning. Forklift capacity, load distribution, and the unit's actual operating weight must be checked before lifting.

 

Applications in Ports and Harbors

 

Port Logistics Fleets
Supports on-site refueling for port service vehicles and logistics fleets, helping simplify fleet fuel supply planning.

Terminal Ground Equipment
Suitable for compatible forklifts and other ground equipment, subject to fuel type and dispensing requirements.

Port Fuel Supply Projects
Provides a configurable fuel storage and dispensing unit for port contractors, equipment suppliers, and project integrators.

 

71

 

Safety Design and Operating Conditions

 

Tank Safety and Site Requirements
The double-wall structure and explosion-suppression material provide additional tank safety measures. Site-specific requirements for ventilation, grounding, spill control, and fire protection must be confirmed before installation.

Explosion-Proof Electrical Arrangement
The unit can be configured with explosion-protected electrical components. Equipment ratings and certification requirements must be matched to the site's hazardous-area classification and local regulations.

Operating Temperature
The stated ambient operating range is -40°C to +60°C. Confirm component suitability and any required environmental options for the intended operating conditions.

Port-Site Environmental Requirements
For coastal installations, specify the required corrosion protection, coating system, and enclosure ingress protection to suit local humidity and salt exposure.

 

Configurations and Customization

 

Tank Capacity and Dimensions
Custom dimensions can be discussed based on site space and storage requirements.

Pump and Dispensing Configuration
Pump type, dispensing flow rate, and nozzle options can be selected according to fuel type and refueling demand.

Control Options
Manual or card-based operation may be available, depending on the selected configuration. Confirm metering, access control, and interface requirements before ordering.

External Appearance and Branding
Exterior color and logo customization are available upon confirmation of artwork, coating specifications, and labeling requirements.

 

Quality Control and Compliance

 

Pressure and Leak Testing
Tank and piping inspections can include pressure or leak testing according to applicable design requirements. Relevant test records can be confirmed for the supplied unit.

Explosion Protection Verification
Installed explosion-protected components should match the specified ratings and applicable certificates. Relevant documentation can be confirmed before ordering.

Functional Testing
Pre-shipment checks can cover pump operation, fuel dispensing, control functions, electrical connections, and configured safety functions.

Standards and Third-Party Inspection
Applicable CE, ATEX, IECEx, or UL requirements should be confirmed against the product scope and supporting documentation. Third-party inspection by SGS or Bureau Veritas (BV) can be arranged by agreement.

 

72

 

73

 

FAQ

 

Q: How can I get a quotation for the Self Contained Fuel Station for Ports?

A: Provide the required capacity, fuel type, order quantity, destination port, and any customization needs. A quotation can then be prepared based on the selected configuration and shipping terms.

Q: What is the minimum order quantity (MOQ)?

A: MOQ can be confirmed based on the selected model and configuration. Please contact us for single-unit purchases or bulk orders.

Q: What is the typical production lead time?

A: Standard configurations typically require around 4–8 weeks after order confirmation and specification approval. Customized designs or additional inspections may require more time.

Q: What payment terms are available?

A: Payment terms can be discussed during quotation. The agreed terms, deposit, and balance payment schedule will be specified in the sales contract.

Q: What warranty is provided?

A: The complete unit carries a 12-month warranty. Core pump components and explosion-proof motors carry an 18-month warranty, subject to the agreed warranty terms.

Q: Can you provide documents for customs clearance and project acceptance?

A: Available documents can be confirmed according to the order and destination requirements, including commercial invoices, packing lists, shipping documents, and applicable product or inspection records.

Hot Tags: self contained fuel station for ports, China self contained fuel station for ports manufacturers, suppliers, factory, Self Contained Diesel Station, self contained fuel station, Self Contained Fuel Station for Mining, Self Contained Fuel Station for Ports, Self Contained Fuel Station with Tank, Self Contained Refueling Unit

Next
No Information

Send Inquiry

(0/10)

clearall